Tilt-table test
The tilt-table test is described in MeSH as a standard and widely accepted diagnostic test used to identify patients who have a vasodepressive and/or cardioinhibitory response as a cause of syncope. The introduction of a 2026 Cureus study (CC BY) says it is commonly used in clinical practice to evaluate patients with unexplained syncope, that it allows assessment of autonomic and cardiovascular responses to orthostatic stress, and that it plays a key role in distinguishing between syncope mechanisms such as orthostatic hypotension and vasovagal syncope. It adds that interpretation traditionally relies primarily on hemodynamic parameters, including blood pressure and heart rate changes. The sources read do not describe how the test is carried out, how accurate it is, or who should have it.
Also called Tilt table test · Head-up tilt table test · Tilt-table testing
- Intervention
- In this atlas
Overview
Technical summary
MeSH D018667 (Tilt-Table Test, exact), last updated 2013-07-09. The scope note cites a textbook; only its first sentence is used. The Cureus article is a retrospective single-centre study of electrocardiographic and haemodynamic changes during tilt-table testing in patients with syncope; only the background statements in its introduction are used, not its results. No sensitivity, specificity, protocol, contraindication or risk is given by either source, so none is stated.
About this intervention
- Type
- Test
- Mechanism
- The test allows assessment of autonomic and cardiovascular responses to orthostatic stress, and its interpretation traditionally relies primarily on blood pressure and heart rate changes (introduction of a 2026 Cureus study).
Claims and evidence
Context People evaluated for syncope with a tilt-table test (MeSH scope note and a Cureus study introduction)
- Recipient
- Recipient not specified
- Population
- Patients who have a vasodepressive or cardioinhibitory response as a cause of syncope (MeSH) and patients with unexplained syncope (the Cureus introduction). Only background statements are used, not the study results.
- Care setting
- Not stated for the statements used; the Cureus study was done in a hospital in Kaunas, Lithuania.
- Geography
- Not stated. The sources read do not name a country.
- Life stage
- Not stated for the statements used; the Cureus study included adults aged 18 or older.
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (a description of a symptom, condition or test).
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Syncope, including unexplained syncope
- Excluded
- None stated
MeSH describes the tilt-table test as a standard and widely accepted diagnostic test used to identify patients who have a vasodepressive and/or cardioinhibitory response as a cause of syncope. The introduction of a 2026 Cureus study says tilt-table testing is commonly used in clinical practice to evaluate patients with unexplained syncope and plays a key role in distinguishing between syncope mechanisms such as orthostatic hypotension and vasovagal syncope.
Applies to Recipient not specified People evaluated for syncope with a tilt-table test (MeSH scope note and a Cureus study introduction)
- Certainty method
- Not assessed
- Limitations
- A vocabulary scope note and background statements from the introduction of one study. Neither gives accuracy figures, a protocol, or who should have the test.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (3)
-
Supports MeSH scope note for descriptor D018667 (Tilt-Table Test)
- Locator
- scopeNote.@value, sentence 1
- How it applies
- What the test is used to identify.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
fcfbfe7c74d629844e917c8a41d680180850f1b620b57bc019ccb946f5d7aab4- Reuse basis
- The NLM web policies page (sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55, hash only; re-fetched 2026-11-19) says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. Source: National Library of Medicine. This copy was fetched on 2026-11-18 and may not reflect the most current data. The raw bytes are committed in the atlas repository.
-
Supports Electrocardiographic and Hemodynamic Changes During Tilt-Table Testing in Patients With Syncope
- Locator
- Introduction, para 1, sentence 3
- How it applies
- Commonly used to evaluate unexplained syncope.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
c846fed244e9522b238cf0a5c96accc961e77cb57bdef778afe0ff773396a11b- Reuse basis
- PMC Open Access subset article under the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense, CC BY 4.0). The licence was read from the full permissions element of the article XML, which says the article is distributed under the Creative Commons Attribution License CC-BY 4.0, with no non-commercial or no-derivatives wording. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed in the atlas repository.
-
Supports Electrocardiographic and Hemodynamic Changes During Tilt-Table Testing in Patients With Syncope
- Locator
- Introduction, para 1, sentence 4 (part)
- How it applies
- Distinguishing syncope mechanisms such as orthostatic hypotension and vasovagal syncope.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
c846fed244e9522b238cf0a5c96accc961e77cb57bdef778afe0ff773396a11b- Reuse basis
- PMC Open Access subset article under the Creative Commons Attribution licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense, CC BY 4.0). The licence was read from the full permissions element of the article XML, which says the article is distributed under the Creative Commons Attribution License CC-BY 4.0, with no non-commercial or no-derivatives wording. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed in the atlas repository.
Clinical links
Each link reports what one cited claim says about one population. "Evaluated for" means studied, not shown to work. These links do not show that anything is effective or right for you.
-
Claim, not a settled fact Used to evaluate unexplained syncope: Fainting (syncope)
Applies to Recipient not specified People evaluated for syncope with a tilt-table test (MeSH scope note and a Cureus study introduction)
MeSH describes the tilt-table test as a standard and widely accepted diagnostic test used to identify patients who have a vasodepressive and/or cardioinhibitory response as a cause of syncope. The introduction of a 2026 Cureus study says tilt-table testing is commonly used in clinical practice to evaluate patients with unexplained syncope and plays a key role in distinguishing between syncope mechanisms such as orthostatic hypotension and vasovagal syncope.Limitations. A vocabulary scope note and background statements from the introduction of one study. Neither gives accuracy figures, a protocol, or who should have the test.
-
Claim, not a settled fact Helps distinguish orthostatic hypotension from other syncope mechanisms: Orthostatic hypotension
Applies to Recipient not specified People evaluated for syncope with a tilt-table test (MeSH scope note and a Cureus study introduction)
MeSH describes the tilt-table test as a standard and widely accepted diagnostic test used to identify patients who have a vasodepressive and/or cardioinhibitory response as a cause of syncope. The introduction of a 2026 Cureus study says tilt-table testing is commonly used in clinical practice to evaluate patients with unexplained syncope and plays a key role in distinguishing between syncope mechanisms such as orthostatic hypotension and vasovagal syncope.Limitations. A vocabulary scope note and background statements from the introduction of one study. Neither gives accuracy figures, a protocol, or who should have the test.
Record details
- Record id
cardio:tilt-table-test- Content hash
6df0bf46e3dd4dc2effa1000dc20576a3c47711e664c53f40e9db3b6070752f4