Ankle-brachial index

The ankle-brachial index, or ABI, is a comparison of blood pressure at the arm and at the ankle. MeSH describes it as a comparison of the blood pressure between the brachial artery and the posterior tibial artery, and as a predictor of peripheral arterial disease. A narrative review says it is often used for initial diagnosis of peripheral artery disease because it is non-invasive and less expensive and more accessible than imaging studies, and that it is calculated by dividing systolic blood pressure at the ankle by systolic blood pressure at the arm. The same review says the test is often under-utilized or performed incorrectly in general practice.

Also called ABI · Ankle brachial index · Ankle-brachial pressure index

  • Intervention
  • In this atlas

Overview

Technical summary

MeSH Ankle Brachial Index (D055109, exact); the existing glossary term for the ankle-brachial index cites the same scope note. The record rests on that scope note, a 2021 open-access narrative review of automated ABI measurement (PMC8585080, CC BY 4.0) and a 2023 open-access review of chronic limb-threatening ischemia (PMC10095037, CC BY 4.0) that names the index among the abnormal hemodynamic parameters in a diagnosis. Cut-off values, the measurement method and the review's findings on automated devices are not repeated, and the atlas gives no rule for reading a result. Whether any measuring device is regulated or cleared was not checked.

About this intervention

Type
Test
Mechanism
Systolic blood pressure at the ankle is divided by systolic blood pressure at the arm (a narrative review); MeSH describes a comparison of blood pressure between the brachial and posterior tibial arteries.

Claims and evidence

Context People who may have peripheral artery disease (MeSH scope note and two reviews)

Recipient
Recipient not specified
Population
People who may have peripheral artery disease or chronic limb-threatening ischemia, as the MeSH scope note and the reviews describe them. The automated-measurement review also discusses people with no symptoms; its device comparisons are not used.
Care setting
Primary care and vascular clinics, as the narrative review describes where the test can be done.
Geography
Not stated for the reviews as a whole.
Life stage
Adults are implied but not stated. This record makes no statement about pregnancy, newborns or children.
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (a description of a test).
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Suspected or established peripheral artery disease
Excluded
None stated
  • Description Evidence synthesis Certainty not assessed

    MeSH describes the ankle-brachial index as a comparison of the blood pressure between the brachial artery and the posterior tibial artery and as a predictor of peripheral arterial disease. A 2021 narrative review (Journal of Clinical Medicine) says it is often used for initial diagnosis of peripheral artery disease because it is non-invasive and less expensive and more accessible than imaging studies, says it is calculated by dividing systolic blood pressure at the ankle by systolic blood pressure at the arm, and says that, according to several studies, the test is often under-utilized or performed incorrectly in general practice. A 2023 review of chronic limb-threatening ischemia says its diagnosis needs pain associated with at least one abnormal hemodynamic parameter, such as the ankle brachial index.

    Applies to Recipient not specified People who may have peripheral artery disease (MeSH scope note and two reviews)

    Certainty method
    Not assessed
    Limitations
    A vocabulary scope note and two narrative reviews, with no study data of the atlas's own. The reviews give cut-off values, measurement methods and automated device findings, which are not repeated; the atlas gives no rule for reading a result. The underuse statement cites other studies.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (6)
    1. Supports Chronic Limb-Threatening Ischemia and the Need for Revascularization

      Publication · Journal of Clinical Medicine · Edition PMC Open Access subset full-text XML, from NCBI E-utilities (J Clin Med 2023;12), fetched 2026-11-18. A narrative review. Used for what chronic limb-threatening ischemia is, the hemodynamic measures named in its diagnosis, and the limits the review states on choosing a revascularization strategy; the trial results, classification thresholds and guideline details it discusses are not used. · PMCID: PMC10095037 · PMID: 37048765 · DOI: 10.3390/jcm12072682

      Locator
      Introduction, 1.1 Background and Definitions, para 4, sentence 5 (part)
      How it applies
      A review of chronic limb-threatening ischemia names the ankle brachial index among the abnormal hemodynamic parameters that go with ischemic rest pain in its diagnosis.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      1bf40be5eee462217350ea27e088333d0294ff4fdbe1136b6cffc5edd8f9f7bb
      Reuse basis
      PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed in the atlas repository.
    2. Supports MeSH scope note for descriptor D055109 (Ankle Brachial Index)

      Dataset · U.S. National Library of Medicine · Edition MeSH linked-data record of the preferred concept M0513882 of descriptor D055109, fetched 2026-10-30. The scope note is on this concept record, not on the descriptor record. · MeSH: M0513882

      Locator
      scopeNote.@value, sentence 1
      How it applies
      MeSH: a comparison of blood pressure between the brachial artery and the posterior tibial artery.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      c3a54e18c9262a3262bcd5611484563d5d3f41e5d5d03c36de3cbd979c87f24a
      Reuse basis
      The NLM web policies page (fetched 2026-10-30, sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55, hash only) says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. Source: National Library of Medicine. This copy was fetched on 2026-10-30 and may not reflect the most current data. The raw bytes are committed in the atlas repository.
    3. Supports MeSH scope note for descriptor D055109 (Ankle Brachial Index)

      Dataset · U.S. National Library of Medicine · Edition MeSH linked-data record of the preferred concept M0513882 of descriptor D055109, fetched 2026-10-30. The scope note is on this concept record, not on the descriptor record. · MeSH: M0513882

      Locator
      scopeNote.@value, sentence 2
      How it applies
      MeSH: it is a predictor of peripheral arterial disease.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      c3a54e18c9262a3262bcd5611484563d5d3f41e5d5d03c36de3cbd979c87f24a
      Reuse basis
      The NLM web policies page (fetched 2026-10-30, sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55, hash only) says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. Source: National Library of Medicine. This copy was fetched on 2026-10-30 and may not reflect the most current data. The raw bytes are committed in the atlas repository.
    4. Supports Automated Measurements of Ankle-Brachial Index: A Narrative Review

      Publication · Journal of Clinical Medicine · Edition PMC Open Access subset full-text XML, from NCBI E-utilities (J Clin Med 2021;10), fetched 2026-11-18. A narrative review. Used only for what the ankle-brachial index is, how it is calculated and its place in first diagnosis; the device accuracy findings are not used. · PMCID: PMC8585080 · PMID: 34768679 · DOI: 10.3390/jcm10215161

      Locator
      1. Introduction, para 2, sentence 1
      How it applies
      The review says the index is often used for initial diagnosis of peripheral artery disease because it is non-invasive and less expensive and more accessible than imaging studies.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      073059498a9dd82f5647cd10b9be812ddb09a0360388975f51c7e7ae315729fa
      Reuse basis
      PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed in the atlas repository.
    5. Supports Automated Measurements of Ankle-Brachial Index: A Narrative Review

      Publication · Journal of Clinical Medicine · Edition PMC Open Access subset full-text XML, from NCBI E-utilities (J Clin Med 2021;10), fetched 2026-11-18. A narrative review. Used only for what the ankle-brachial index is, how it is calculated and its place in first diagnosis; the device accuracy findings are not used. · PMCID: PMC8585080 · PMID: 34768679 · DOI: 10.3390/jcm10215161

      Locator
      1. Introduction, para 2, sentence 3
      How it applies
      The review says the index is calculated by dividing systolic blood pressure at the ankle by systolic blood pressure at the arm.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      073059498a9dd82f5647cd10b9be812ddb09a0360388975f51c7e7ae315729fa
      Reuse basis
      PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed in the atlas repository.
    6. Background Automated Measurements of Ankle-Brachial Index: A Narrative Review

      Publication · Journal of Clinical Medicine · Edition PMC Open Access subset full-text XML, from NCBI E-utilities (J Clin Med 2021;10), fetched 2026-11-18. A narrative review. Used only for what the ankle-brachial index is, how it is calculated and its place in first diagnosis; the device accuracy findings are not used. · PMCID: PMC8585080 · PMID: 34768679 · DOI: 10.3390/jcm10215161

      Locator
      1. Introduction, para 2, sentence 9 (part)
      How it applies
      The review says that, according to several studies, the test is often under-utilized or performed incorrectly in general practice.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      073059498a9dd82f5647cd10b9be812ddb09a0360388975f51c7e7ae315729fa
      Reuse basis
      PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed in the atlas repository.

Clinical links

Each link reports what one cited claim says about one population. "Evaluated for" means studied, not shown to work. These links do not show that anything is effective or right for you.

Record details

Record id
cardio:ankle-brachial-index
Content hash
a7d3ec0755fb7fd65ee9ffb88b5be7609c90b42f1f7f6d263a8d54901918493a