{
  "release_id": "a25293eeae6350fb",
  "id": "cardio:pulse-wave-velocity-and-arterial-stiffness",
  "owner": "cardio",
  "kind": "intervention",
  "slug": "pulse-wave-velocity-and-arterial-stiffness",
  "name": "Pulse wave velocity and arterial stiffness testing",
  "aliases": [
    "Pulse wave velocity",
    "PWV",
    "Arterial stiffness measurement",
    "Carotid-femoral pulse wave velocity"
  ],
  "atlases": [
    "cardio"
  ],
  "summary_plain": "A way to assess how stiff the arteries are by timing how fast the pressure wave of the pulse travels between two places along them. MeSH defines pulse wave velocity as the transit time of an aortic pressure wave between two places along the arteries, determined in part by arterial stiffness. A systematic review calls arterial stiffness, as determined by pulse wave velocity, a recognized marker of cardiovascular risk, and says the higher the velocity, the lower the vessel's elasticity.",
  "summary_technical": "MeSH matches are broad: Pulse Wave Analysis (D063177) holds Pulse Wave Velocity as a non-preferred concept (M0571694, the source of the first scope note), and Vascular Stiffness (D059289) is the stiffness descriptor; neither descriptor is this test alone. The record rests on those two scope notes and on a 2024 systematic review of device validation studies (PMC11671637, CC BY 4.0). The review says there are currently no clear guidelines on which patient groups should undergo measurement and that more research in larger populations is needed before noninvasive devices enter daily practice. Device names, accuracy results, reference values and thresholds are not recorded, and the atlas gives no rule for using the test. No patient-facing page was used.",
  "editorial_state": "draft",
  "last_substantive_edit": "2026-11-09",
  "last_evidence_check": "2026-11-09",
  "next_review_due": null,
  "identifiers": [
    {
      "scheme": "mesh",
      "value": "D063177",
      "normalized_value": "D063177",
      "match": "broad",
      "version": "MeSH linked-data descriptor record fetched on 2026-11-09, lastUpdated 2013-01-01; the record states no yearly MeSH release",
      "label": null,
      "from_source": false
    },
    {
      "scheme": "mesh",
      "value": "D059289",
      "normalized_value": "D059289",
      "match": "broad",
      "version": "MeSH linked-data descriptor record fetched on 2026-11-09 (lastUpdated 2012-07-03); the record states no yearly MeSH release",
      "label": null,
      "from_source": false
    }
  ],
  "navigation": {
    "cardio": {
      "system": [
        "blood-vessels"
      ],
      "condition-area": [
        "risk-and-prevention",
        "hypertension"
      ]
    }
  },
  "payload": {
    "subtype": "test",
    "mechanism": "Timing the pulse wave between two measurement sites along the arteries, as an indirect measure of how rigid they are; the higher the velocity, the lower the vessel's elasticity (systematic review).",
    "components": null
  },
  "content_digest": "597350940c76d81eeeacc688facd7bb3698f82487aa3fc9e20923c83dac38b41",
  "review": {
    "content_digest": "597350940c76d81eeeacc688facd7bb3698f82487aa3fc9e20923c83dac38b41",
    "current": [],
    "conflicting": [],
    "stale": [],
    "inactive": []
  },
  "claims": [
    {
      "release_id": "a25293eeae6350fb",
      "id": "cardio:claim-pwv-arterial-stiffness-marker-review",
      "owner": "cardio",
      "subject_entity_id": "cardio:pulse-wave-velocity-and-arterial-stiffness",
      "category": "descriptive",
      "statement": "A 2024 systematic review (Cardiology Research and Practice) calls arterial stiffness, as determined by pulse wave velocity, a recognized marker of cardiovascular risk. It describes pulse wave velocity as a well-established, indirect measure of vascular rigidity, says the higher the velocity the lower the vessel's elasticity, and says the predictive value of arterial stiffness is particularly strong in people with hypertension and those at higher baseline cardiovascular risk. MeSH says increased arterial stiffness is one of the risk factors for many cardiovascular diseases.",
      "context": {
        "id": "cardio:ctx-pwv-arterial-stiffness-review",
        "label": "Arterial stiffness statements in a systematic review of noninvasive measurement",
        "recipient": "unknown",
        "population": "The statements come from the review's abstract and introduction, which draw on the wider literature. The review's own included studies focused on populations with chronic diseases who were hemodynamically stable.",
        "care_setting": "Not stated. The review discusses office-based and catheter-based measurement.",
        "geography": "Not stated for the review as a whole.",
        "life_stage_note": "Not restricted in the introduction. The review excluded studies of pregnancy, hemodynamic shock and stress tests; this record makes no statement about those groups, or about children.",
        "life_stage_terms": null,
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (a review of measurement methods).",
        "eligibility": {
          "inclusion": [
            "People whose arterial stiffness is measured, as described in the review"
          ],
          "exclusion": []
        }
      },
      "evidence_stage": "synthesis",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "A systematic review of device validation studies; the statements come from its abstract and introduction, which cite other studies, not from its own findings. The review itself says there are currently no clear guidelines on which patient groups should undergo measurement and that more research in larger populations is needed before noninvasive devices enter daily practice. Device accuracy results and guideline thresholds are not repeated.",
      "editorial_state": "draft",
      "checked_at": "2026-11-09",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "Abstract, Objective, sentence 1",
          "applicability_note": "Arterial stiffness determined by pulse wave velocity is a recognized marker of cardiovascular risk.",
          "snapshot": {
            "id": "cardio:pmc-pmc11671637-2026-11-09",
            "retrieved_at": "2026-11-09T13:16:55Z",
            "content_hash": "9f6c127a3b0ccb35ca097cae25060560da26eca31b49c9e6924e9cf237792fd5",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "cardio:pmc-pmc11671637",
            "source_type": "publication",
            "title": "Evaluation of Arterial Stiffness Parameters Measurement With Noninvasive Methods—A Systematic Review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11671637/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC11671637",
                "normalized_value": "PMC11671637",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "39734755",
                "normalized_value": "39734755",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1155/crp/4944517",
                "normalized_value": "10.1155/crp/4944517",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Cardiology Research and Practice",
            "edition": "PMC Open Access subset full-text XML, from NCBI E-utilities (Cardiol Res Pract 2024;2024), fetched 2026-11-09. A systematic review of device validation studies. Used only for what pulse wave velocity and arterial stiffness are and for the limits it states; the device brand names, accuracy findings and guideline values are not used.",
            "reuse_basis": "PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed at research/snapshots/w4k20-pmc-PMC11671637.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Introduction, para 2, sentences 1 and 2",
          "applicability_note": "Pulse wave velocity is an indirect measure of vascular rigidity; higher velocity means lower elasticity.",
          "snapshot": {
            "id": "cardio:pmc-pmc11671637-2026-11-09",
            "retrieved_at": "2026-11-09T13:16:55Z",
            "content_hash": "9f6c127a3b0ccb35ca097cae25060560da26eca31b49c9e6924e9cf237792fd5",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "cardio:pmc-pmc11671637",
            "source_type": "publication",
            "title": "Evaluation of Arterial Stiffness Parameters Measurement With Noninvasive Methods—A Systematic Review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11671637/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC11671637",
                "normalized_value": "PMC11671637",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "39734755",
                "normalized_value": "39734755",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1155/crp/4944517",
                "normalized_value": "10.1155/crp/4944517",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Cardiology Research and Practice",
            "edition": "PMC Open Access subset full-text XML, from NCBI E-utilities (Cardiol Res Pract 2024;2024), fetched 2026-11-09. A systematic review of device validation studies. Used only for what pulse wave velocity and arterial stiffness are and for the limits it states; the device brand names, accuracy findings and guideline values are not used.",
            "reuse_basis": "PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed at research/snapshots/w4k20-pmc-PMC11671637.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Introduction, paragraph beginning Arterial stiffness not only increases, sentence 3",
          "applicability_note": "The predictive value is particularly strong in people with hypertension and those at higher baseline risk.",
          "snapshot": {
            "id": "cardio:pmc-pmc11671637-2026-11-09",
            "retrieved_at": "2026-11-09T13:16:55Z",
            "content_hash": "9f6c127a3b0ccb35ca097cae25060560da26eca31b49c9e6924e9cf237792fd5",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "cardio:pmc-pmc11671637",
            "source_type": "publication",
            "title": "Evaluation of Arterial Stiffness Parameters Measurement With Noninvasive Methods—A Systematic Review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11671637/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC11671637",
                "normalized_value": "PMC11671637",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "39734755",
                "normalized_value": "39734755",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1155/crp/4944517",
                "normalized_value": "10.1155/crp/4944517",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Cardiology Research and Practice",
            "edition": "PMC Open Access subset full-text XML, from NCBI E-utilities (Cardiol Res Pract 2024;2024), fetched 2026-11-09. A systematic review of device validation studies. Used only for what pulse wave velocity and arterial stiffness are and for the limits it states; the device brand names, accuracy findings and guideline values are not used.",
            "reuse_basis": "PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed at research/snapshots/w4k20-pmc-PMC11671637.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "context",
          "locator": "Introduction, paragraph beginning Despite the high predictive value, sentence 1",
          "applicability_note": "The review says there are no clear guidelines on which patient groups should be measured.",
          "snapshot": {
            "id": "cardio:pmc-pmc11671637-2026-11-09",
            "retrieved_at": "2026-11-09T13:16:55Z",
            "content_hash": "9f6c127a3b0ccb35ca097cae25060560da26eca31b49c9e6924e9cf237792fd5",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "cardio:pmc-pmc11671637",
            "source_type": "publication",
            "title": "Evaluation of Arterial Stiffness Parameters Measurement With Noninvasive Methods—A Systematic Review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11671637/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC11671637",
                "normalized_value": "PMC11671637",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "39734755",
                "normalized_value": "39734755",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1155/crp/4944517",
                "normalized_value": "10.1155/crp/4944517",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Cardiology Research and Practice",
            "edition": "PMC Open Access subset full-text XML, from NCBI E-utilities (Cardiol Res Pract 2024;2024), fetched 2026-11-09. A systematic review of device validation studies. Used only for what pulse wave velocity and arterial stiffness are and for the limits it states; the device brand names, accuracy findings and guideline values are not used.",
            "reuse_basis": "PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed at research/snapshots/w4k20-pmc-PMC11671637.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "context",
          "locator": "Abstract, Conclusions",
          "applicability_note": "More research on a larger population is needed before noninvasive devices enter daily practice.",
          "snapshot": {
            "id": "cardio:pmc-pmc11671637-2026-11-09",
            "retrieved_at": "2026-11-09T13:16:55Z",
            "content_hash": "9f6c127a3b0ccb35ca097cae25060560da26eca31b49c9e6924e9cf237792fd5",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "cardio:pmc-pmc11671637",
            "source_type": "publication",
            "title": "Evaluation of Arterial Stiffness Parameters Measurement With Noninvasive Methods—A Systematic Review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC11671637/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC11671637",
                "normalized_value": "PMC11671637",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "39734755",
                "normalized_value": "39734755",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1155/crp/4944517",
                "normalized_value": "10.1155/crp/4944517",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Cardiology Research and Practice",
            "edition": "PMC Open Access subset full-text XML, from NCBI E-utilities (Cardiol Res Pract 2024;2024), fetched 2026-11-09. A systematic review of device validation studies. Used only for what pulse wave velocity and arterial stiffness are and for the limits it states; the device brand names, accuracy findings and guideline values are not used.",
            "reuse_basis": "PMC Open Access subset article under the Creative Commons Attribution 4.0 licence (https://creativecommons.org/licenses/by/4.0/, content-type ccbylicense). The article's own license element states the licence. The XML is committed unaltered, with the citation and licence kept in the file. The raw file is committed at research/snapshots/w4k20-pmc-PMC11671637.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "scopeNote.@value, sentences 1 and 2",
          "applicability_note": "MeSH: pulse wave velocity is the transit time of an aortic pressure wave, determined in part by arterial stiffness.",
          "snapshot": {
            "id": "cardio:mesh-scope-m0571694-2026-11-09",
            "retrieved_at": "2026-11-09T13:16:02Z",
            "content_hash": "f81408f9c33319e42cb3056ab516dae4474763751b5996096abd2f7166dc7b61",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "cardio:mesh-scope-m0571694",
            "source_type": "dataset",
            "title": "MeSH scope note for concept M0571694 (Pulse Wave Velocity, a concept of Pulse Wave Analysis)",
            "canonical_url": "https://id.nlm.nih.gov/mesh/M0571694",
            "identifiers": [
              {
                "scheme": "mesh",
                "value": "M0571694",
                "normalized_value": "M0571694",
                "match": "exact",
                "version": "id.nlm.nih.gov linked data, concept M0571694 of descriptor D063177, retrieved 2026-11-09",
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "U.S. National Library of Medicine",
            "edition": "MeSH linked-data record of the concept M0571694 of descriptor D063177, fetched 2026-11-09. The scope note is on this concept record, not on the descriptor record. Pulse Wave Velocity is a non-preferred concept of Pulse Wave Analysis; the preferred concept is M0571693.",
            "reuse_basis": "The NLM web policies page (sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55, hash only) says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. The NLM MeSH terms and conditions page (sha256 f33b14141a5b6c8a2b1464c751dbdbb0a0d476c913851bf2a8c3d5c14b1afce7, hash only) asks redistributors to maintain current data or to make known that their copy may not reflect the most current data. This copy was fetched on 2026-11-09 and may not reflect the most current data. The raw bytes are committed at research/snapshots/w4k20-meshc-M0571694.json.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "scopeNote.@value, sentence 2",
          "applicability_note": "MeSH: increased arterial stiffness is one of the risk factors for many cardiovascular diseases.",
          "snapshot": {
            "id": "cardio:mesh-scope-d059289-2026-11-09",
            "retrieved_at": "2026-11-09T13:16:17Z",
            "content_hash": "1f3471f2e54ad509a9ae3ec383a5f2a53e57c87b672a6224d6cd212c2fafc94e",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "cardio:mesh-scope-d059289",
            "source_type": "dataset",
            "title": "MeSH scope note for descriptor D059289 (Vascular Stiffness)",
            "canonical_url": "https://id.nlm.nih.gov/mesh/M0550340",
            "identifiers": [
              {
                "scheme": "mesh",
                "value": "M0550340",
                "normalized_value": "M0550340",
                "match": "exact",
                "version": "id.nlm.nih.gov linked data, preferred concept M0550340 of descriptor D059289, retrieved 2026-11-09",
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "U.S. National Library of Medicine",
            "edition": "MeSH linked-data record of the preferred concept M0550340 of descriptor D059289, fetched 2026-11-09. The scope note is on this concept record, not on the descriptor record.",
            "reuse_basis": "The NLM web policies page (sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55, hash only) says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. The NLM MeSH terms and conditions page (sha256 f33b14141a5b6c8a2b1464c751dbdbb0a0d476c913851bf2a8c3d5c14b1afce7, hash only) asks redistributors to maintain current data or to make known that their copy may not reflect the most current data. This copy was fetched on 2026-11-09 and may not reflect the most current data. The raw bytes are committed at research/snapshots/w4k20-meshc-M0550340.json.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "09c9baacfe6faf974f1c2a3b7b0def5f24ad67b62604702a6803f9072d42b7dc",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/cardio--claim-pwv-arterial-stiffness-marker-review.json"
    }
  ],
  "decisions": [],
  "milestones": [],
  "relationships": {
    "outgoing": [
      {
        "predicate": "evaluated_for",
        "label": "Review: the predictive value of arterial stiffness is particularly strong in people with hypertension",
        "clinical_claim_not_fact": true,
        "family": "clinical",
        "other_entity_id": "core:hypertension",
        "other_entity_in_atlas": true,
        "claim_id": "cardio:claim-pwv-arterial-stiffness-marker-review",
        "evidence": null,
        "primary": false,
        "role": null,
        "valid_from": null,
        "valid_to": null
      },
      {
        "predicate": "part_of",
        "label": "Filed under this front",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "cardio:front-diagnostics-and-imaging",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": true,
        "role": null,
        "valid_from": null,
        "valid_to": null
      }
    ],
    "incoming": []
  },
  "page_path": "interventions/pulse-wave-velocity-and-arterial-stiffness/",
  "context_path": "api/v1/context/cardio--pulse-wave-velocity-and-arterial-stiffness.md"
}
