  "release_id": "a25293eeae6350fb",
  "id": "cardio:embolic-protection-devices",
  "owner": "cardio",
  "kind": "technology",
  "slug": "embolic-protection-devices",
  "name": "Embolic protection devices",
  "aliases": [
    "Embolic protection device",
    "Embolic capture device"
  ],
  "atlases": [
    "cardio"
  ],
  "summary_plain": "An embolic protection device is a filter or blocking device used during a procedure inside a blood vessel. Its job, as MeSH describes it, is to protect the organ downstream from blood clots or debris that the procedure knocks loose. The US regulator's definition of one product type, the temporary carotid catheter for embolic capture, is a catheter with a capture filter or an occlusion balloon at its far end, used to capture embolic material in a way that may protect against stroke. This page records no trial results and does not say when a device should be used.",
  "summary_technical": "MeSH D057505 (Embolic Protection Devices), exact. The US regulator product code NTE, Temporary Carotid Catheter For Embolic Capture, is device class 2 under 21 CFR 870.1250. The openFDA definition text for NTE is cut off in the data, ending mid-sentence after \"while performing angioplasty and stenting procedures\", so the full list of intended uses is not recorded. Other US regulator product types are not covered here. No outcome data are recorded.",
  "editorial_state": "draft",
  "last_substantive_edit": "2026-11-08",
  "last_evidence_check": "2026-11-08",
  "next_review_due": null,
  "identifiers": [
    {
      "scheme": "mesh",
      "value": "D057505",
      "normalized_value": "D057505",
      "match": "exact",
      "version": "id.nlm.nih.gov linked data, retrieved 2026-11-08",
      "label": null,
      "from_source": false
    },
    {
      "scheme": "fda-product-code",
      "value": "NTE",
      "normalized_value": "NTE",
      "match": "broad",
      "version": "openFDA device classification endpoint, retrieved 2026-11-08 (dataset last updated 2026-10-26)",
      "label": "Temporary Carotid Catheter For Embolic Capture",
      "from_source": false
    },
    {
      "scheme": "cfr",
      "value": "21 CFR 870.1250",
      "normalized_value": "21 CFR 870.1250",
      "match": "broad",
      "version": null,
      "label": null,
      "from_source": false
    }
  ],
  "navigation": {
    "cardio": {
      "system": [
        "blood-vessels",
        "brain"
      ],
      "condition-area": [
        "coronary-and-vascular-disease",
        "stroke"
      ]
    }
  },
  "payload": {
    "principle": "A filter or occlusive device sits in the vessel during an endovascular procedure and mechanically shields the organ downstream from clots or debris that the procedure dislodges (MeSH scope note). In the US regulator's carotid product type, a catheter carries a capture filter or an occlusion balloon at its distal end.",
    "strengths": [
      "The US regulator's definition says the filter or balloon captures embolic material in a manner that may protect or prevent a stroke or other cerebral vascular sequelae.",
      "The US regulator's definition says the device is indicated for use as a guidewire and embolic protection system to contain and remove embolic material (thrombus or debris)."
    ],
    "limitations": [
      "The word \"may\" is the US regulator's own: the definition states an intended effect, and no source read reports whether it is achieved.",
      "The openFDA definition is truncated, and the sources read give no outcomes, risks or patient selection.",
      "The US regulator product type read is for the carotid arteries. MeSH uses the term for endovascular procedures in general."
    ],
    "required_infrastructure": [
      "A percutaneous catheter system introduced into an artery through the skin using a guidewire, used while performing angioplasty and stenting procedures (the US regulator definition)."
    ]
  },
  "content_digest": "9db0eaa77e6fde4b339be4d0f51b95f03c76a0f90e994cf2758b6c60c45868e2",
  "review": {
    "content_digest": "9db0eaa77e6fde4b339be4d0f51b95f03c76a0f90e994cf2758b6c60c45868e2",
    "current": [],
    "conflicting": [],
    "stale": [],
    "inactive": []
  },
  "claims": [],
  "decisions": [],
  "milestones": [],
  "relationships": {
    "outgoing": [
      {
        "predicate": "related_to",
        "label": "Related condition: the product type named here is for carotid use",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "cardio:carotid-stenosis",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": false,
        "role": null,
        "valid_from": null,
        "valid_to": null
      },
      {
        "predicate": "related_to",
        "label": "Related condition",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "cardio:ischemic-stroke",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": false,
        "role": null,
        "valid_from": null,
        "valid_to": null
      },
      {
        "predicate": "part_of",
        "label": "Filed under this front",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "cardio:front-devices-and-monitoring",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": true,
        "role": null,
        "valid_from": null,
        "valid_to": null
      }
    ],
    "incoming": []
  },
  "page_path": "technologies/embolic-protection-devices/",
  "context_path": "api/v1/context/cardio--embolic-protection-devices.md"
}