# Implantable loop recorder

Technology · id `cardio:implantable-loop-recorder` · Cardiovascular Atlas · release `a25293eeae6350fb` (public)

> General information from published sources, not medical advice, and not reviewed by clinicians. Check the cited source before relying on anything here. Sponsors do not influence what this atlas says.

The atlas's own text and curation may be reused under Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0, https://creativecommons.org/licenses/by-nc/4.0/): credit the atlas, and do not use it commercially without a licence from the owner. See the atlas About page. Text quoted from a source stays under that source's own terms, given as the source's reuse\_basis. The atlas's reuse terms do not cover it. The downloads list each quotation with its source in third\_party\_quotations.

Also called: ILR; Insertable loop recorder; Insertable cardiac monitor; ICM

Browse, organ or system: Heart  
Browse, condition area: Heart rhythm problems  

## In plain language

An implantable loop recorder is a heart-rhythm recorder placed under the skin; the manufacturer of one cleared model calls it an insertable cardiac monitor. The device facts on this page come from that one model's 510(k) summary, written by the manufacturer. The summary says the system records the ECG beneath the skin, starting by itself or when the patient sets it off. Its listed uses are people whose clinical syndrome or situation puts them at higher risk of heart rhythm problems, and people with passing symptoms that could point to an arrhythmia, for example dizziness, palpitation, fainting (syncope) or chest pain. The summary adds that the model was not tested in children specifically. Other models may differ. This page records no detection rates and no trial results.

## Technical summary

A MeSH lookup on 2026-11-08 found no descriptor or term for this device. The US regulator product codes MXD (event recorder, implantable cardiac, with arrhythmia detection; class 2, 21 CFR 870.1025) and MXC (without arrhythmia detection; class 2, 21 CFR 870.2800) cover it. The indications are paraphrased from the manufacturer's 510(k) summary of K163460, which concerns the monitor used with a mobile application and a patient connector and repeats the indications of its predicate. The clearance letter and the summary in that document both give product code DSI (21 CFR 870.1025), while the openFDA 510(k) record for the same number gives MXD; this page does not reconcile them. A 2001 clearance record (K011098, product code MXC) uses the name Insertable Loop Recorder System, which is the source of the alias. No battery life, monitoring period or arrhythmia-detection performance is recorded.

## Connected pages

- Related condition group: Arrhythmia (heart rhythm problems) (`cardio:arrhythmia`)
- Filed under this front: Devices and monitoring (`cardio:front-devices-and-monitoring`)

## Registry records

Records a program assembled from a public registry; no person wrote or checked them. They are counted here, not listed: the JSON record of this page lists each one in its relationships.

- 4 registry trials

## Provenance

Content hash: 6b66f432ba83f9ea2e3e22f1cc37ceb089e01a9a93228694239cb14c7710d555
Last substantive edit: 2026-11-08
Evidence last checked: 2026-11-08
